Technical Data:
Temperature range:
-40°C to +90°C
Maximum temperature at conductor: +120°C
Short circuit temperature:
200°C (short circuit duration up to 5 s)
Nominal voltage:
VDE 600/1000 V AC
1800 V DC conductor/conductor
AC test voltage:
10000 V
Minimum bending radius:
Flexing: 10x cable Ø
Fixed installation: 4x cable Ø
Highest permissible voltage:
– DC: Conductor/Conductor 1.8 kV, Conductor/Earth 0.9 kV
– AC: Conductor/Earth 0.7 kV
– Three-phase: Conductor/Conductor 1.2 kV
Cable Structure:
– Tinned copper conductor, to DIN VDE 0295 cl.5, fine wire, IEC 60228 cl.5
– Core insulation of cross-linked Polyolefin
– Core identification: white
– Outer sheath of cross-linked Polyolefin
– Sheath colour: please refer to the table below
– With meter marking
Properties:
– Double-insulated
– Ozone resistant according to EN 50396
– Weather and UV resistant according to HD 605/A1
– Halogen-free according to DIN EN 50267-2-1, EN 60684-2
– Resistant to acid and bases according to EN 60811-2-1
– Flame retardant to DIN VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1-2
– Very robust and abrasion-resistant sheath according to DIN EN 53516
– Anticipated service life: 25 years
– Hydrolysis and ammoniac resistant
Approvals:
– According to PV1-F requirement profile for PV cable DKE/VDE AK 411.2.3
– VDE (Reg. 8266)
– TÜV (2 PfG 1169 / 08.2007, R60025298)
– UL certification in progress (UL Subject 4703)
Application:
The SOLARFLEX®-X PV1-F cable is specifically designed for cabling solar modules. It meets the requirements of the PV1-F profile for PV cables. Please note that it is not suitable for direct installation in the ground.
CE: This product conforms with Low-Voltage Directive 2014/35/EU.